× Heads up!

Aqua Data Studio / nhilam

Follow
IDE for Relational Databases
×
ranarohitp(*) reported 2015-07-16T04:48:33Z  · tariqrahiman last modified 2015-07-28T19:45:09Z

BIGINT data type does not support identity,disable IDENTITY option for BIGINT data type.


Priority Low
Complexity Unknown
Component DB - Sap Hana
Version 17.0
Product: Aqua Data Studio
Version: 17.0.0-dev-81
Build #: 44750
Build Date: 2015-Jul-15 05:45:31 PM
 
Operating Environment: Linux (3.13.0-57-generic, amd64) / UTF-8 / en / IN / Oracle Corporation 1.8.0_40-b26
Memory: Max=4,433,379,328;  Total=1,152,909,312;  Free=770,546,880;  CPUs=8
 
 
1. Connect to SAP Hana database.
2. Expand Schemas object folder.
3. Expand your own schema & go to Tables object folder.
4. Right click on Tables object folder & select "Create Table" option.
5. In Create Table window:
  -Enter Table name.
  -Add one column having BIGINT datatype.
6. Go to Columns panel and set identity to Yes

7. Click on create button, a error message "SAP DBTech JDBC: [7] (at 39): feature not supported: cannot create row table having  identity column: col1: line 2 col 2 (at pos 39)" is displayed.

8.  BIGINT data type does not support identity, and we should disable this option for BIGINT data type as we do for other data types.

1 attachment

Issue #13513

Closed
Invalid
Resolved 2015-07-28T00:00:09Z
 
 
Completion
No due date
No fixed build
No time estimate

About AquaClusters Privacy Policy Support Version - 19.0.2-4 AquaFold, Inc Copyright © 2007-2017