vaibhavladdha271(*) reported 2015-12-23T04:56:27Z  · rachanag(*) last modified 2016-12-14T12:21:58Z

Reference line label is displayed at inappropriate position if band reference line is applied on parameter & table calculation is applied on measure field


Priority Low
Complexity Unknown
Component Visual Analytics
Version 18.0
Product: Aqua Data Studio
Version: 17.0.0-ga-10
Build #: 47925
Build Date: 2015-Dec-21 05:16:10 PM
 
Operating Environment: Linux (3.13.0-71-generic, amd64) / UTF-8 / en / IN / Oracle Corporation 1.8.0_40-b26
Memory: Max=704,643,072;  Total=303,562,752;  Free=201,948,408;  CPUs=8
 
Scenario 1:

1.Dnd a dimension in Columns deck.
2.Dnd a measure in Rows deck.
3.Right click on axis of chart & select Add reference line option.
Switch to Band tab
Select Per cell option.
Select create parameter option from value field of 'band from' pane.
In create parameter window keep default settings as it is & click on OK.
In reference line window click on OK.
Reference line is displayed.
4.Right click on measure field in Rows deck & select Add table calculation option.
In add table calculation window keep default settings as it is & click on OK.

OR
Open attached 14078.vizx
GO to Scenario1 sheet

Actual result: Reference line is displayed but label for parameter is not displayed at appropriate position.

Expected result: Reference line label for parameter should be displayed at appropriate position.

Scenario 2:
1.Dnd a dimension in Columns deck
2.Dnd 2 measures in Rows deck
3.Click on Axes deck & select Merged axes->Clustered option.
4.Right click on first measure field in rows deck & select Add table calculation option.
In add table calculation window keep default settings as it is & click on OK.
5.Right click on second measure field in rows deck & select Add table calculation option.
In add table calculation window keep default settings as it is & click on OK.
6.Right click on axis of chart & select Add reference line option.
Switch to Band tab
Select Per cell option.
Select create parameter option from Value field of 'Band from' pane.
In create parameter window keep default settings as it is & click on OK.
In reference line window click on OK.

OR
Open attached 14078.vizx
Go to Scenario2 sheet

Actual result: Reference line label for parameter is not displayed at appropriate position.

Observation: This only happens in case of parameters.
This only happens for Band reference line.
This happens for 'Per cell' scope only.
This issue occurs for dual axis chart also.
Labels are displayed properly on swapping rows & columns(i.e for Horizontal bar chart.)

Broken build: 17-rc-51 

 

8 attachments

Issue #14078

Closed
Fixed
Resolved 2016-02-03T20:43:53Z
 
 