× Heads up!

Aqua Data Studio / nhilam

Follow
IDE for Relational Databases
×
nileshhmali reported Mar 3, 2017  · tariqrahiman last modified Mar 31, 2017

Schema compare filter is not removed after Click on Refresh icon.


Priority Low
Complexity Unknown
Component Tools - Compare - Schema
Version 18.0

 

Product: Aqua Data Studio
Version: 18.0.1-9
Build #: 53441
Build Date: 2017-Mar-02 04:03:12 PM
 
Operating Environment: Linux (4.4.0-64-generic, amd64) / UTF-8 / en / US / Oracle Corporation 1.8.0_102-b14
Memory: Max=704,643,072;  Total=383,254,528;  Free=208,742,632;  CPUs=8
 
 
Connect any database(e.g DB2-LUW-11.1)
 
CREATE TABLE "DB_LEFT"."test_c1"  ( 
"c1" VARCHAR(25),
"c2" VARCHAR(25) 
)
IN "USERSPACE1"
ORGANIZE BY ROW 
DATA CAPTURE NONE
COMPRESS NO
GO
 
 
Open Schema compare result tab with created table.
Click on filter icon.
Schema compare filter window opens
Uncheck Table object and click on OK button.
Click on Refresh icon
 
Actual Result:
You can see that Schema compare filter is not removed after clicking on Refresh icon
 
Expected Result:
Schema compare filter should be removed after clicking on Refresh icon
 
 
Observation:
1)I have pressed shortcut key Refresh(F5) after applying the filter.
=>Schema compare filter is removed.
 
2)ADS-17.0.0 behavior:
=>Schema compare filter is removed after Clicking on Refresh icon.
 
 
  Windows Ubuntu
Latest build ADS 18.0.1-9 Y Y
Broken build ADS-18.0.0-dev-232 Y Y
Working build ADS-18.0.0-dev-231 N N
Y - Yes, issue reproduced.
N-issue is not reproduced.   

 

1 attachment
  • 1.png

    Mar 3, 2017

    208 KB

Issue #15055

Closed
Fixed
Resolved Mar 29, 2017
 
 
Completion
No due date
Fixed Build ADS 18.0.6-4 and ADS 19.0.0-dev-10
No time estimate

About AquaClusters Privacy Policy Support Version - 19.0.2-4 AquaFold, Inc Copyright © 2007-2017